Home > Equipment > Object Terminals > AS006M
Object Terminal “Anteaus” AS006M “Phoenix”
Being a part of transmitting system “Antaeus” this equipment
is designed for central guard of domestic/industrial premises and
prevention of infiltration and fire. This goal is achieved by
monitoring of system loops with installed alarm/fire annunciators
and by sending alarm messages to the central surveillance console or
the user’s mobile phone. There are four channels for sending
messages (one or several are used depending on operation or type of
connection):
· urban telephone network
· mobile network GSM (by setting dial-up connection)
· radio channel LARS
· retranslator TS through used telephone line – “Phobos
3”, “Altair”, “Atlas-3”, “Atlas-6”
In case of damage other channels are used. There are three
data formats for sending messages to the CSC, the usual ADEMCO ID
Contact, ADEMCO Express or the new “Presto” format, characterized by
higher reliability, speed and mimic resistance. Mobile messages are
sent as SMS.
OT can divide the guarded areas into sections and
control them separately. Each section is attached to a group of
users and each o them is authorized to control only his/her section.
In order to engage/disengage the security system use the
side-mounted keyboard for each section or the remote control/
electronic key coming with the equipment. You can also make an
emergency call with the remote.
OT has got an attached interface for different external
devices such as side-mounted keyboard two/four-wired area expanders,
relay modules of area expanders
In case of intrusion into the guarded object press the help
button. Otherwise the fire suppressing gauge of the OT will send a
message to the CSC, installed at the company providing service of
the object. On receiving the message the service company identifies
the address, the type of intrusion with other identification signs
and takes measures targeted at property protection and criminal
apprehension.
There exist two version of OT, differing in type of link
channel. Have a look at them at the table below:
version |
Telephone line |
GSM |
LARS |
TS “Phobos-3” |
AS006M-G |
+ |
+ |
- |
+ |
AS006M-L |
+ |
- |
- |
+ |
AS006M-R |
+ |
- |
+ |
- |
AS006M-M |
- |
+ |
+ |
- |
The operating and monitoring of OT is done with the help of
remote keyboard such as ADEMCO-6128 or ADEMCO06139. As a rule each
guarded section is attached to a separate keyboard (the system allow
simultaneous using of different keyboards in different sections),
but there is a possibility of creating a section unattached to a
keyboard (in this case it is run with a remote or electronic key).
OT has got a remote single indicator showing the current
state of the first section. If several remote indicators are
required (in other sections) they can be connected through the
relay. . It may be single light-emitting diode or light annunciator
with voltage 12V (e.g. annunciator “Mayak”).
OT enforces provides up to seven alarm system loops. The
source voltage for three main loops is 12V. OT registers closed,
normal and open conditions of the loops with “normal”, “fast” and
“special” modes. Protect mode registers 5 conditions, that is
normal, one sensor functioning, two and more sensors functioning,
loop closure and loop break.
OT supports 56 guarded areas. Additional areas can be
involved by the following means:
· through the
wireless expander 5881 (any annunciator ADEMCO 58XX is allowable);
· through
fourwired expanders ADEMCO4229 (there may be four expanders each
attached to 8 guarded areas);
· through
two-wired expanders ADEMCO 4208, 4190.
All the areas may be randomly divided into guarded sections,
each section is run individually. OT supports up to 7 sections.
OT allows connecting loop-powered sensors, with source
voltage 12V and total input current 0.6 mA in customary mode and 1.5
mA in “special” mode. It is also possible to install sensors with
external power supply – OT itself, for example, provided that
current-carrying rating (0.8 A for all peripheral units) is
observed.
The mode for each zone is programmed individually.
The main loops’ characteristics are given n the table:
Source voltage |
12V |
Nominal value of loop resistance
- modes “normal”, “fast”, “protected”
- special mode |
2.2 kOhm
12 kOhm |
Lowest operating threshold
- modes
“normal”, “fast”
- special
mode
- protect
mode |
1.4 kOhm
1.4 kOhm
1.79, 1.26, 0.75 kOhm |
Highest operating threshold
- modes
“normal”, “fast”
- special
mode
- protect
mode |
3.4 kOhm
15 kOhm
2.65, 3.67, 15 kOhm |
Hump resistance of loop wires |
0.5 kOhm |
Terminal resistance of loop leakage |
20 kOhm |
Operating time in normal mode |
400 ms |
Operating time in fast mode |
60 ms |
OT allows sending alarm/service messages from all the
sections to the CSC through one or two telephone numbers reaching 13
symbols. If necessary different prefixes can be set for sending on
the phone and GSM.
Versions G, M allow sending SMS through the user’s mobile
phone. SMS support may be turned on/off for each guarded section
individually, each section may have its own phone number for sending
SMS.
OT supports GSM net within 900/1800 mHz, Phase 2+, class 4
(900 mHz, 2W) and class 1 (1800 mHz, 1W) and phone interface
according to Russian State Standard GOST 25007-81. Both impulse and
tone dialing is supported.
OT supports three FTP:
· ADEMCO ID
Contact;
· ADEMCO Express;
· “Presto”.
The OT may automatically monitor the fund balance of the
cellular service provider notifying the CSC and sending SMSs to the
cell user. User can also check his/her balance at any moment.
OT makes it possible using up to nine remote controls and
electronic keys iButtons for each section, with unique codes and
identification. It’s also possible to use more remote, but in this
case some of them should have identical codes.
The OT provides remote controls Keeloq with “rolling” code
which prevents imitation. They are used for engaging/disengaging the
security system within the perimeter (omitting defective areas) and
doing an emergency call. Some of these functions may not be
activated.
The OT registers crack attempts and notifies CSC in time.
OT supports programmable delay (0…198s) at the input/output
for each section individually.
OT provides control of system loops, primary power supply,
battery backup state of charge, service information integrity, state
of GSM-modem, registration in GSM-net, telephone working order, LARS
transmitter, and expander modules each time before engaging the
security system and at any moment by user’s require. At the same
time OT allows engaging in case of failures (loops breaks as well)
OT may send SMSs from the user’s mobile phone. A certain
message may engage/disengage the security system, do a test, turn
on/off the relay (all these functions or some of them may be
inactivated). For reasons of safety each SMS must have an
identification number and a password.
Coming with OT is an event-programmed relay for connecting
peripheral units (light/sound annunciator). Hump current is 2A,
maximal voltage – 400 V. The relays are operated regardless
pre-specified events and time. OT may operate the expanders relay
and control up to 9 relays. Each relay may be switched on/off
according to the pre-specified event at a certain moment or with the
help of the keyboard.
OT supports event log for 128 events.
OT keeps up to nine user’s passwords for each section, as
well as administrator’s password and forcing password, preventing
illegal intrusion.
OT may periodically send status messages to the CSC. The
interval of sending status messaged may be 4…36 hours.
OT also offers on-line diagnostics of loops and connection
with CSC.
It also makes possible connecting of auxiliary equipment such
as light/sound indicators with voltage 12V. The total current must
not exceed 0.8 A.
OT is powered through the AC network 220V (+22-33), 50±1Hz.
The maximum wattage is 25W. OT has got a backup supply source that
is battery FIAM-GS with capacity 4.5 ampere-hour. The switching to
the backup supply source and charging at presence of the primary
power supply are automatic. With fully charged battery OT operates
during 24 hours (without auxiliary equipment). In case of battery
running out OT sends message to CSC.
The temperature of the premises where OT is set should be
+1-+40 C, with relative humidity up to 90% at temperature 25C (group
SN4 according to Russian State Standard (GOST) 15150?69).
OT provides electromagnetic compatibility according to
hardness group 3, GOST 50009092.
OT size should not exceed 200x210x60mm, weight is 4 kg at
most.
Configuration of OT versions is shown below:
Version |
G |
R |
L |
M |
Object terminal AS996M |
1 |
1 |
1 |
1 |
Remote keyboard |
1 |
1 |
1 |
1 |
Light-emitting diode ÀË397Á ÀÀ0.336.076ÒÓ |
1 |
1 |
1 |
1 |
Antenna ADA-0062 |
1 |
- |
- |
1 |
Antenna LARS |
- |
1 |
- |
1 |
Resistor C2-33-0.25 2.2kOhm ÎÆÎ 467. 173 ÒÓ |
7 |
7 |
7 |
7 |
Remote control |
4 |
4 |
4 |
4 |
Operation manual |
1 |
1 |
1 |
1 |
Package |
1 |
1 |
1 |
1 |
The type of the side-mounted keyboard is ordered
individually. By customer require the set may include a large number
of keyboards, remote controls and electronic keys.
|