Home > Equipment > Object Terminals > AS006MObject Terminal “Anteaus” AS006M “Phoenix” Being a part of transmitting system “Antaeus” this equipment is designed for central guard of domestic/industrial premises and prevention of infiltration and fire. This goal is achieved by monitoring of system loops with installed alarm/fire annunciators and by sending alarm messages to the central surveillance console or the user’s mobile phone. There are four channels for sending messages (one or several are used depending on operation or type of connection):
· urban telephone network
· mobile network GSM (by setting dial-up connection)
· radio channel LARS
· retranslator TS through used telephone line – “Phobos 3”, “Altair”, “Atlas-3”, “Atlas-6”
In case of damage other channels are used. There are three data formats for sending messages to the CSC, the usual ADEMCO ID Contact, ADEMCO Express or the new “Presto” format, characterized by higher reliability, speed and mimic resistance. Mobile messages are sent as SMS.
OT can divide the guarded areas into sections and control them separately. Each section is attached to a group of users and each o them is authorized to control only his/her section.
In order to engage/disengage the security system use the side-mounted keyboard for each section or the remote control/ electronic key coming with the equipment. You can also make an emergency call with the remote.
OT has got an attached interface for different external devices such as side-mounted keyboard two/four-wired area expanders, relay modules of area expanders
In case of intrusion into the guarded object press the help button. Otherwise the fire suppressing gauge of the OT will send a message to the CSC, installed at the company providing service of the object. On receiving the message the service company identifies the address, the type of intrusion with other identification signs and takes measures targeted at property protection and criminal apprehension.
There exist two version of OT, differing in type of link channel. Have a look at them at the table below:
version |
Telephone line |
GSM |
LARS |
TS “Phobos-3” |
AS006M-G |
+ |
+ |
- |
+ |
AS006M-L |
+ |
- |
- |
+ |
AS006M-R |
+ |
- |
+ |
- |
AS006M-M |
- |
+ |
+ |
- |
The operating and monitoring of OT is done with the help of remote keyboard such as ADEMCO-6128 or ADEMCO06139. As a rule each guarded section is attached to a separate keyboard (the system allow simultaneous using of different keyboards in different sections), but there is a possibility of creating a section unattached to a keyboard (in this case it is run with a remote or electronic key).
OT has got a remote single indicator showing the current state of the first section. If several remote indicators are required (in other sections) they can be connected through the relay. . It may be single light-emitting diode or light annunciator with voltage 12V (e.g. annunciator “Mayak”).
OT enforces provides up to seven alarm system loops. The source voltage for three main loops is 12V. OT registers closed, normal and open conditions of the loops with “normal”, “fast” and “special” modes. Protect mode registers 5 conditions, that is normal, one sensor functioning, two and more sensors functioning, loop closure and loop break.
OT supports 56 guarded areas. Additional areas can be involved by the following means:
· through the wireless expander 5881 (any annunciator ADEMCO 58XX is allowable);
· through fourwired expanders ADEMCO4229 (there may be four expanders each attached to 8 guarded areas);
· through two-wired expanders ADEMCO 4208, 4190.
All the areas may be randomly divided into guarded sections, each section is run individually. OT supports up to 7 sections.
OT allows connecting loop-powered sensors, with source voltage 12V and total input current 0.6 mA in customary mode and 1.5 mA in “special” mode. It is also possible to install sensors with external power supply – OT itself, for example, provided that current-carrying rating (0.8 A for all peripheral units) is observed.
The mode for each zone is programmed individually.
The main loops’ characteristics are given n the table:
Source voltage |
12V |
Nominal value of loop resistance
- modes “normal”, “fast”, “protected”
- special mode |
2.2 kOhm
12 kOhm |
Lowest operating threshold
- modes “normal”, “fast”
- special mode
- protect mode |
1.4 kOhm
1.4 kOhm
1.79, 1.26, 0.75 kOhm |
Highest operating threshold
- modes “normal”, “fast”
- special mode
- protect mode |
3.4 kOhm
15 kOhm
2.65, 3.67, 15 kOhm |
Hump resistance of loop wires |
0.5 kOhm |
Terminal resistance of loop leakage |
20 kOhm |
Operating time in normal mode |
400 ms |
Operating time in fast mode |
60 ms |
OT allows sending alarm/service messages from all the sections to the CSC through one or two telephone numbers reaching 13 symbols. If necessary different prefixes can be set for sending on the phone and GSM.
Versions G, M allow sending SMS through the user’s mobile phone. SMS support may be turned on/off for each guarded section individually, each section may have its own phone number for sending SMS.
OT supports GSM net within 900/1800 mHz, Phase 2+, class 4 (900 mHz, 2W) and class 1 (1800 mHz, 1W) and phone interface according to Russian State Standard GOST 25007-81. Both impulse and tone dialing is supported.
OT supports three FTP:
· ADEMCO ID Contact;
· ADEMCO Express;
· “Presto”.
The OT may automatically monitor the fund balance of the cellular service provider notifying the CSC and sending SMSs to the cell user. User can also check his/her balance at any moment.
OT makes it possible using up to nine remote controls and electronic keys iButtons for each section, with unique codes and identification. It’s also possible to use more remote, but in this case some of them should have identical codes.
The OT provides remote controls Keeloq with “rolling” code which prevents imitation. They are used for engaging/disengaging the security system within the perimeter (omitting defective areas) and doing an emergency call. Some of these functions may not be activated.
The OT registers crack attempts and notifies CSC in time.
OT supports programmable delay (0…198s) at the input/output for each section individually.
OT provides control of system loops, primary power supply, battery backup state of charge, service information integrity, state of GSM-modem, registration in GSM-net, telephone working order, LARS transmitter, and expander modules each time before engaging the security system and at any moment by user’s require. At the same time OT allows engaging in case of failures (loops breaks as well)
OT may send SMSs from the user’s mobile phone. A certain message may engage/disengage the security system, do a test, turn on/off the relay (all these functions or some of them may be inactivated). For reasons of safety each SMS must have an identification number and a password.
Coming with OT is an event-programmed relay for connecting peripheral units (light/sound annunciator). Hump current is 2A, maximal voltage – 400 V. The relays are operated regardless pre-specified events and time. OT may operate the expanders relay and control up to 9 relays. Each relay may be switched on/off according to the pre-specified event at a certain moment or with the help of the keyboard.
OT supports event log for 128 events.
OT keeps up to nine user’s passwords for each section, as well as administrator’s password and forcing password, preventing illegal intrusion.
OT may periodically send status messages to the CSC. The interval of sending status messaged may be 4…36 hours.
OT also offers on-line diagnostics of loops and connection with CSC.
It also makes possible connecting of auxiliary equipment such as light/sound indicators with voltage 12V. The total current must not exceed 0.8 A.
OT is powered through the AC network 220V (+22-33), 50±1Hz. The maximum wattage is 25W. OT has got a backup supply source that is battery FIAM-GS with capacity 4.5 ampere-hour. The switching to the backup supply source and charging at presence of the primary power supply are automatic. With fully charged battery OT operates during 24 hours (without auxiliary equipment). In case of battery running out OT sends message to CSC.
The temperature of the premises where OT is set should be +1-+40 C, with relative humidity up to 90% at temperature 25C (group SN4 according to Russian State Standard (GOST) 15150?69).
OT provides electromagnetic compatibility according to hardness group 3, GOST 50009092.
OT size should not exceed 200x210x60mm, weight is 4 kg at most.
Configuration of OT versions is shown below:
Version |
G |
R |
L |
M |
Object terminal AS996M |
1 |
1 |
1 |
1 |
Remote keyboard |
1 |
1 |
1 |
1 |
Light-emitting diode ÀË397Á ÀÀ0.336.076ÒÓ |
1 |
1 |
1 |
1 |
Antenna ADA-0062 |
1 |
- |
- |
1 |
Antenna LARS |
- |
1 |
- |
1 |
Resistor C2-33-0.25 2.2kOhm ÎÆÎ 467. 173 ÒÓ |
7 |
7 |
7 |
7 |
Remote control |
4 |
4 |
4 |
4 |
Operation manual |
1 |
1 |
1 |
1 |
Package |
1 |
1 |
1 |
1 |
The type of the side-mounted keyboard is ordered individually. By customer require the set may include a large number of keyboards, remote controls and electronic keys. |